Plant Documentation For each electrical plant the regulations e. A Lightning Assessment will clarify the kind and of the electrical damage, the damaging process and the verifiable and measureable impact of the damage. BS or VGB R require a plant documentation, which has to report the following data and plans Distribution panel and single line drawings Grid system and safeguarding Grid parameters and short circuit power Electrical Safety Equipment fuses, MCBs, MCCBs and RCUs Grounding material and grounding resistance measurement Grounding wire and equi-potential bonding Mains and distribution cables Sockets and outlets indication of room use The plant documentation has to be compiled and filed by the construction company. However, special attention is paid to the chronological changes of electrical parameters. The commissioning report ensures, that the plant can be started-up in a save wy and according to the relevant standards and regulations. However there could still be single overvoltage events, damaging the input of the device e.
Uploader: | Torisar |
Date Added: | 8 December 2008 |
File Size: | 21.21 Mb |
Operating Systems: | Windows NT/2000/XP/2003/2003/7/8/10 MacOS 10/X |
Downloads: | 7531 |
Price: | Free* [*Free Regsitration Required] |
For each electrical plant the regulations e.
Elektrotechnik Josef Reiterer
The plant documentation has to be compiled and filed by the construction company. However, special attention is paid to the chronological changes of electrical parameters. It is a mandatory part of the plant documentation.
BS or VGB R require a plant documentation, which has to report the following data and plans Distribution panel and single line drawings Grid system and safeguarding Grid parameters and short circuit power Electrical Safety Equipment fuses, MCBs, MCCBs and RCUs Grounding material and grounding resistance measurement Grounding wire and equi-potential bonding Mains and distribution cables Sockets and outlets indication of room use The plant documentation has to be compiled and filed by the construction company.
The measurements at the recurring electrical inspection are similar to those at plant commissioning.
Old safety gear and switches often do not provide sufficient protection resulting in dangers of electric shocks or danger of fire.
It gives the client, the authorities and insurance companies the needed confirmation about the safe and flawless state of teh plant.
The commissioning report ensures, that the plant can be started-up in a save wy and according to the relevant standards and regulations. In case no plant documentation is available a replacement plant documentation has to be compiled a the recurring inspection.
Electrical Inspection
At commissioning elejtrotechnik electrical installation is verified according to the respective standards and regulations for construction or extension e. Appliances connected to the electric sockets in a building that is hit by flash lightning are especially prone to damage, when an overvoltage of the lightning across the earthing resistance, this can lead to dangerous overvoltages in electrical appliances.
A professional Lightning Protection System according to BS EN with sufficient dimensioning of lightning rods, lightning conductors and surge arrestors helps to reduce the impact of lightning events. A Lightning Assessment will clarify the kind and of the electrical damage, the damaging process and the verifiable and measureable impact of the damage. The purpose of the recurring inspection according to BS or Anlagenbucy is the assessment and anlagejbuch of all electrical plant data.
Anlagenbuch inhalt
However there could still be single overvoltage events, damaging the input of the device e. Next to optical checks several electrical measurements are done to reconstruct the entrance path of the overvoltage. The recurring inspection is typically stipulated in the permits of commercial buildings.
Plant Documentation For each electrical plant the regulations e. Lightning can destroy electrical appliances directly or indirectly. Electrical devices and plants are subject to aging, which can cause deterioration of electrical parameters e.